ETL sertifikatlangan UL standarti SPT-3 mis quvvat kabeli

Qisqa Tasvir:

Nominal harorat: 60ºC, 75ºC, 90ºC, 105ºC
Nominal kuchlanish: 300V
Malumot standarti: UL62, UL1581 & CSA C22.2N NO.49
Yalang'och, torli mis o'tkazgich

Sertifikat: ETL, CETL


Mahsulot detali

TSS

Mahsulot teglari

MODEL SPT-3
Qo'llash doirasi
Issiqlikka chidamlilik
Brend DABU
dirijyor Tarmoqli, qalaylangan yoki yalang'och mis o'tkazgich
Ishlab chiqarish tajribasi 30 YIL
Ranglar Moslashtirilgan rang bo'lishi mumkin
Qadoqlash 100m / Rulo yoki mijozning talabiga binoan, Plastik plyonkali qadoqlash yoki rulonlarni o'rash
Xizmat OEM, ODM
Savdo belgisi DABU
Ishlab chiqarish quvvati 300000 km

 

Materialning shakli Yassi sim
Sertifikatlash
ISO9001, ETL, RoHS, REACH
Yadrolar soni Bir yadroli yoki ko'p yadroli
Yetkazib berish vaqti 15 YOKI 25 KUN
Kompaniya turi Ishlab chiqaruvchi
Xizmat
OEM, ODM
ASLI Xitoy
Namuna bepul
Transport paketi Bobin/spool/karton/plet/
HS kodi 8544492100

Mahsulot tavsifi

UL standarti RoHS muvofiqligi Spt-3 PVC tekis quvvat kabeli

ETL C(ETL) modeli: SPT-3 standartlari: UL62

Nominal harorat: 60ºC, 75ºC, 90ºC, 105ºC
Nominal kuchlanish: 300V
Malumot standarti: UL62, UL1581 & CSA C22.2N NO.49
Yalang'och, torli mis o'tkazgich
Rangli qo'rg'oshinsiz PVX izolyatsiyasi va ko'ylagi
ETL VW-1 va CETL FT1 vertikal olov sinovidan o'tadi
Ilova: Uy soatlari, fanatlar, radio va shunga o'xshash asboblarda foydalanish uchun

 

Supero'tkazuvchilar soni

Nominal maydon (mm2)

Nominal qalinligi
izolyatsiyasi (mm)

Nominal qalinligi
g'ilofdan (mm)

Oʻrtacha OD(mm)

2

18(0,824)

1.52

/

4,4*8,8

17(1,04)

1.52

/

4,6*9,2

16(1,31)

1.52

/

4,7*9,5

15(1,65)

2.03

/

5,8*11,6

14(2.08)

2.03

/

6,0*12,0

12(3,31)

2.41

/

7,5*14,0

10(5,26)

2.79

/

8,8*17,6

3

18(0,824)

1.52

/

4,4*10,8

17(1,04)

1.52

/

4,6*11,5

16(1,31)

1.52

/

4,7*12,0

15(1,65)

2.03

/

5,8*13,5

14(2.08)

2.03

/

6,0*14,5

12(3,31)

2.41

/

7,5*16,0

10(5,26)

2.79

/

8,8*19,0

ETL APPROVAL markalash bo'yicha ko'rsatma

1. Belgilar - Mahsulot quyidagicha belgilangan: Kabel ko'ylagi belgisi: Quyidagi ma'lumotlar kabellar tashqi ko'ylagi yuzasida 600 mm (24 dyuym) maksimal oraliqda bosilgan siyoh bilan yozilgan:1.Kabel ishlab chiqaruvchisi / kompaniya nomi yoki savdo belgisi2.Turni belgilash 3.Maksimal harorat darajasi 4.Supero'tkazuvchilar soni va o'lchamlari ("AWG" va "mm2" ham kerak)5.Kuchlanish darajasi 6."VW-1" yoki "FT1" yoki "FT2"7."c(ETL)us" logotipi (ixtiyoriy)8.ETL nazorat raqami (agar kabel ishlab chiqaruvchisi / kompaniya nomi chop etilgan bo'lsa, ixtiyoriy)9."QALQONLI" (qalqonli shnurlar uchun)10."METAL QO'LLANISH A'ZO'SI" (metall yadrosi bilan ta'minlangan shnurlar uchun) Yorliq yoki yuk tashish yorlig'i belgilari: Yorliq yoki yuk yorlig'ida quyidagi ma'lumotlar paydo bo'ladi:1."ETL ro'yxati" (ixtiyoriy)2.Kabel ishlab chiqaruvchisi / kompaniya nomi yoki savdo nomi3."VW-1" yoki "FT1" yoki "FT2"4."c(ETL)us" logotipi (ixtiyoriy)5.ETL nazorat raqami (agar kabel ishlab chiqaruvchisi / kompaniya nomi chop etilgan bo'lsa, ixtiyoriy)6.Ishlab chiqarilgan sana (oy va yil)7.Turni belgilash 8.Kuchlanish darajasi 9.Supero'tkazuvchilar soni va o'lchamlari10.Uzunlik belgilari (ixtiyoriy).

 


  • ETL sertifikatlangan UL standarti SPT-3 mis quvvat kabeli tafsilotlari rasmlari

  • Oldingi:
  • Keyingisi: